Title :
Breakdown process of a rod-to-plane gap in atmospheric air under DC voltage stress
Author :
Isa, Hiromu ; Sonoi, Yasuo ; Hayashi, Muneaki
Author_Institution :
Osaka Inst. of Technol., Japan
fDate :
4/1/1991 12:00:00 AM
Abstract :
Discharge phenomena were observed under chopped or steady state DC voltage application. A still camera and two photomultipliers were used to record and measure the development of the electrical breakdown in a normal air gap. The breakdown process under both positive and negative DC voltage stress differs from that under impulse voltage. In the case of DC voltage, space charge is produced by corona discharges prior to the complete breakdown, which affects the breakdown process significantly
Keywords :
corona; discharges (electric); electric breakdown of gases; photomultipliers; space charge; DC voltage stress; air; breakdown process; corona discharges; discharge phenomena; electrical breakdown; impulse voltage; photomultipliers; rod-to-plane gap; space charge; still camera; Atmospheric measurements; Breakdown voltage; Cameras; Corona; Electric breakdown; Electric variables measurement; Photomultipliers; Space charge; Steady-state; Stress;
Journal_Title :
Electrical Insulation, IEEE Transactions on