DocumentCode
1541255
Title
A Method to Determine the Existence of Genuine Interharmonics
Author
Hui, Jin ; Xu, Wilsun ; Honggeng Yang
Author_Institution
Coll. of Electr. Eng. & Inf. Technol., Sichuan Univ., Chengdu, China
Volume
27
Issue
3
fYear
2012
fDate
7/1/2012 12:00:00 AM
Firstpage
1690
Lastpage
1692
Abstract
Interharmonic components can often be seen from the discrete Fourier transform (DFT) results of measured voltage or current waveforms. These components may be caused by various factors, such as transient waveform distortions or noises. They are not necessarily related to the real interharmonics. This letter presents a simple method to verify the existence of a genuine interharmonic component contained in the DFT results. The method can also reveal the characteristics of the component. The method has been demonstrated on various field measurement data that contain genuine and false interharmonic components.
Keywords
discrete Fourier transforms; power system harmonics; DFT; current waveforms; discrete Fourier transform; false interharmonic components; field measurement data; genuine interharmonic components; transient waveform distortions; voltage waveforms; Current measurement; Discrete Fourier transforms; Distortion measurement; Furnaces; Harmonic analysis; Transient analysis; Voltage measurement; Fourier analysis; interharmonics; power quality (PQ);
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/TPWRD.2012.2198313
Filename
6218218
Link To Document