• DocumentCode
    1542186
  • Title

    A depth-encoding Anger detector using scintillating fibers

  • Author

    Matthews, Kenneth L., II ; Leonard, Scott M. ; Ordonez, Caesar E. ; Persyk, Dennis E. ; Chang, Wei

  • Author_Institution
    Dept. of Med. Phys., Rush-Presbyterian-St Luke´´s Med. Center, Chicago, IL, USA
  • Volume
    48
  • Issue
    4
  • fYear
    2001
  • fDate
    8/1/2001 12:00:00 AM
  • Firstpage
    1397
  • Lastpage
    1402
  • Abstract
    Parallax error during coincidence imaging with dual-head cameras causes infidelity in tomographic images, worsening as one increases crystal thickness to combat poor detection efficiency. The authors are integrating wavelength-shifting (WLS) scintillating fibers onto a thick NaI(Tl) crystal to create an Anger detector capable of measuring depth-of-interaction (DOI). Our studies target eventual implementation on the large-area detectors of commercial multihead coincidence imaging systems. The prototype detector uses a 127×127×25.4 mm3 NaI(Tl) crystal. The crystal is sealed in a two-windowed aluminum enclosure-both faces of the crystal are coupled optically to glass windows. A ribbon of 125 square 1-mm WLS fibers is coupled lengthwise to the entrance window; enhanced-green- response photomultiplier tubes (PMTs) detect the light from the fibers. The number of fibers exhibiting signals above a threshold value determines the DOI. For interactions near the ribbon, light localizes in only a few fibers; light from distant interactions illuminates many fibers. Four PMTs, for position centroid calculation and energy windowing, are coupled through a light-guide to the exit window of the detector. This paper summarizes the concept of the depth-encoding Anger detector, describes the design of the detector prototype, and details on-going feasibility testing and optimization of the detector
  • Keywords
    biomedical equipment; emission tomography; fibres; image coding; solid scintillation detectors; 1 mm; NaI:Tl; depth-encoding Anger detector; depth-of-interaction measurement; detection efficiency; dual-head cameras; medical diagnostic imaging; medical instrumentation; nuclear medicine; parallax error; scintillating fibers; thick NaI(Tl) crystal; tomographic images; Cameras; Detectors; Optical coupling; Optical fiber testing; Optical imaging; Prototypes; Thickness measurement; Tomography; Wavelength measurement; Windows;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.958364
  • Filename
    958364