• DocumentCode
    1542611
  • Title

    A microstrip germanium detector for position-sensitive X-ray spectroscopy

  • Author

    Protic, D. ; Stöhlker, Th ; Beyer, H.F. ; Bojowald, J. ; Borchert, G. ; Gumberidze, A. ; Hamacher, A. ; Kozhuharov, C. ; Ma, X. ; Mohos, I.

  • Author_Institution
    Inst. fur Kernphys., Forschungszentrum Julich GmbH, Germany
  • Volume
    48
  • Issue
    4
  • fYear
    2001
  • fDate
    8/1/2001 12:00:00 AM
  • Firstpage
    1048
  • Lastpage
    1052
  • Abstract
    For the current X-ray spectroscopy program at the ESR storage ring (GSI-Darmstadt), a position-sensitive germanium detector system was completed. The position-sensitive structure of the detector was realized on an area of 47×23.4 mm by an array of 200 strips (200 μm wide and 23.4 mm long) separated by 35-μm-wide grooves etched through boron implanted contact. The thickness of the detector, including a 0.6-mm-thick Li-diffused rear contact, amounts to 4.1 mm. Each strip has been joined to a preamplifier placed outside the cryostat with printed leads inside the flexible Kapton-foil. The energy resolution of the strips was about 1.8 keV [FWHM] for 60-keV photons. Coincidences between neighboring strips were measured showing that a time resolution of 70 ns [FWHM] was obtained. First preliminary results obtained with the detector mounted at the transmission X-ray spectrometer FOCAL demonstrated that an energy resolution better than 100 eV is achievable together with a high detection efficiency. Along with a new kind of X-ray spectrometer, this detector may play a key role for the next step of high-precision X-ray experiments: aiming for a precise test of quantum electrodynamics in the heaviest one-electron systems, such as hydrogen-like uranium
  • Keywords
    X-ray detection; X-ray spectrometers; germanium radiation detectors; position sensitive particle detectors; ESR storage ring; FOCAL; Ge; boron implanted contact; detection efficiency; energy resolution; microstrip germanium detector; position-sensitive X-ray spectroscopy; position-sensitive structure; preamplifier; transmission X-ray spectrometer; Energy resolution; Germanium; Microstrip; Paramagnetic resonance; Position sensitive particle detectors; Spectroscopy; Storage rings; Strips; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.958721
  • Filename
    958721