DocumentCode :
1543536
Title :
Spatial response of symmetric and asymmetric planar SQUID gradiometers
Author :
Walker, M.E. ; Lang, G. ; Klein, U. ; Pegrum, C.M. ; Donaldson, G.B. ; Cochran, S.
Author_Institution :
Dept. of Phys. & Appl. Phys., Strathclyde Univ., Glasgow, UK
Volume :
7
Issue :
2
fYear :
1997
fDate :
6/1/1997 12:00:00 AM
Firstpage :
3220
Lastpage :
3223
Abstract :
First and second order symmetric gradiometers, and first order singly and doubly asymmetric gradiometers have been designed and fabricated using a standard niobium thin-film process. Here we present the results of our simulations of the effect of varying the gradiometer geometry, order and symmetry. In particular, we are interested in the spatial response of the gradiometer. We compare the simulations with experimental data.
Keywords :
SQUID magnetometers; Nb; asymmetric gradiometer; first order gradiometer; niobium thin-film process; planar SQUID gradiometer; second order gradiometer; simulation; spatial response; symmetric gradiometer; Coils; Copper; Geometry; Magnetic field measurement; Physics; SQUIDs; Solid modeling; Substrates; Thin film devices; Wire;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/77.622031
Filename :
622031
Link To Document :
بازگشت