DocumentCode
1543536
Title
Spatial response of symmetric and asymmetric planar SQUID gradiometers
Author
Walker, M.E. ; Lang, G. ; Klein, U. ; Pegrum, C.M. ; Donaldson, G.B. ; Cochran, S.
Author_Institution
Dept. of Phys. & Appl. Phys., Strathclyde Univ., Glasgow, UK
Volume
7
Issue
2
fYear
1997
fDate
6/1/1997 12:00:00 AM
Firstpage
3220
Lastpage
3223
Abstract
First and second order symmetric gradiometers, and first order singly and doubly asymmetric gradiometers have been designed and fabricated using a standard niobium thin-film process. Here we present the results of our simulations of the effect of varying the gradiometer geometry, order and symmetry. In particular, we are interested in the spatial response of the gradiometer. We compare the simulations with experimental data.
Keywords
SQUID magnetometers; Nb; asymmetric gradiometer; first order gradiometer; niobium thin-film process; planar SQUID gradiometer; second order gradiometer; simulation; spatial response; symmetric gradiometer; Coils; Copper; Geometry; Magnetic field measurement; Physics; SQUIDs; Solid modeling; Substrates; Thin film devices; Wire;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/77.622031
Filename
622031