DocumentCode
154366
Title
Probe dynamics influence on determination of volumetric oxygen transfer coefficient
Author
Niedzwiedz, Malgorzata ; Laszczyk, Piotr
Author_Institution
Inst. of Autom. Control, Silesian Univ. of Technol., Gliwice, Poland
fYear
2014
fDate
2-5 Sept. 2014
Firstpage
395
Lastpage
400
Abstract
This paper deals with practical aspects of volumetric oxygen transfer coefficient determination. The attention was paid to influence of dissolved oxygen probe dynamics on measurements. A new identification method of volumetric oxygen transfer coefficient was developed. This method involves numerical integral calculation. The new method and three other methods (graphical, logarithmic and regression) of determining volumetric oxygen transfer coefficient value were applied. The comparative simulation research was done using dissolved oxygen concentration model. All four methods were finally aplied to real biotechnological wastewater process with the activated sludge.
Keywords
biotechnology; integral equations; sludge treatment; wastewater treatment; activated sludge; biotechnological wastewater process; dissolved oxygen concentration model; dissolved oxygen probe dynamics; graphical method; logarithmic method; numerical integral calculation; probe dynamics; regression method; volumetric oxygen transfer coefficient; Atmospheric modeling; Biological system modeling; Mathematical model; Numerical models; Oxygen; Probes; Wastewater; dissolved oxygen model; dissolved oxygen probe dynamics; volumetric oxygen transfer coefficient;
fLanguage
English
Publisher
ieee
Conference_Titel
Methods and Models in Automation and Robotics (MMAR), 2014 19th International Conference On
Conference_Location
Miedzyzdroje
Print_ISBN
978-1-4799-5082-9
Type
conf
DOI
10.1109/MMAR.2014.6957386
Filename
6957386
Link To Document