DocumentCode :
1545084
Title :
A simple but effective way for cable shielding measurement
Author :
De Leo, R. ; Cerri, G. ; Primiani, V. Mariani ; Botticelli, R.
Author_Institution :
Dipartimento di Elettronica e Autom., Ancona Univ., Italy
Volume :
41
Issue :
3
fYear :
1999
fDate :
8/1/1999 12:00:00 AM
Firstpage :
175
Lastpage :
179
Abstract :
The method of the current probe is used to recover the transfer parameters of coaxial cables. The measurements are carried out by means of only one current probe and using scalar instrumentation, resulting in a very simple and cheap setup compared with other techniques. This paper presents the relative theory showing that the assumption of weak coupling can be adopted; the results obtained for a typical cable are compared with that obtained by the triaxial technique and the line-injection method; a comparison is also performed with theoretical data obtained for the transfer impedance by several models
Keywords :
cable shielding; coaxial cables; electric current measurement; electric impedance; probes; braided shielded cable; cable shielding measurement; coaxial cables; current probe; line-injection method; scalar instrumentation; transfer impedance; transfer parameters recovery; triaxial technique; weak coupling; Cable shielding; Coaxial cables; Current measurement; Electromagnetic measurements; Geometry; Impedance; Power cables; Probes; Solid modeling; Testing;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/15.784151
Filename :
784151
Link To Document :
بازگشت