DocumentCode
1545084
Title
A simple but effective way for cable shielding measurement
Author
De Leo, R. ; Cerri, G. ; Primiani, V. Mariani ; Botticelli, R.
Author_Institution
Dipartimento di Elettronica e Autom., Ancona Univ., Italy
Volume
41
Issue
3
fYear
1999
fDate
8/1/1999 12:00:00 AM
Firstpage
175
Lastpage
179
Abstract
The method of the current probe is used to recover the transfer parameters of coaxial cables. The measurements are carried out by means of only one current probe and using scalar instrumentation, resulting in a very simple and cheap setup compared with other techniques. This paper presents the relative theory showing that the assumption of weak coupling can be adopted; the results obtained for a typical cable are compared with that obtained by the triaxial technique and the line-injection method; a comparison is also performed with theoretical data obtained for the transfer impedance by several models
Keywords
cable shielding; coaxial cables; electric current measurement; electric impedance; probes; braided shielded cable; cable shielding measurement; coaxial cables; current probe; line-injection method; scalar instrumentation; transfer impedance; transfer parameters recovery; triaxial technique; weak coupling; Cable shielding; Coaxial cables; Current measurement; Electromagnetic measurements; Geometry; Impedance; Power cables; Probes; Solid modeling; Testing;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/15.784151
Filename
784151
Link To Document