• DocumentCode
    1545084
  • Title

    A simple but effective way for cable shielding measurement

  • Author

    De Leo, R. ; Cerri, G. ; Primiani, V. Mariani ; Botticelli, R.

  • Author_Institution
    Dipartimento di Elettronica e Autom., Ancona Univ., Italy
  • Volume
    41
  • Issue
    3
  • fYear
    1999
  • fDate
    8/1/1999 12:00:00 AM
  • Firstpage
    175
  • Lastpage
    179
  • Abstract
    The method of the current probe is used to recover the transfer parameters of coaxial cables. The measurements are carried out by means of only one current probe and using scalar instrumentation, resulting in a very simple and cheap setup compared with other techniques. This paper presents the relative theory showing that the assumption of weak coupling can be adopted; the results obtained for a typical cable are compared with that obtained by the triaxial technique and the line-injection method; a comparison is also performed with theoretical data obtained for the transfer impedance by several models
  • Keywords
    cable shielding; coaxial cables; electric current measurement; electric impedance; probes; braided shielded cable; cable shielding measurement; coaxial cables; current probe; line-injection method; scalar instrumentation; transfer impedance; transfer parameters recovery; triaxial technique; weak coupling; Cable shielding; Coaxial cables; Current measurement; Electromagnetic measurements; Geometry; Impedance; Power cables; Probes; Solid modeling; Testing;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/15.784151
  • Filename
    784151