• DocumentCode
    1545127
  • Title

    An automated SAR measurement system for compliance testing of personal wireless devices

  • Author

    Yu, Qishan ; Gandhi, Om P. ; Aronsson, Magnus ; Wu, Ding

  • Author_Institution
    Dept. of Electr. Eng., Utah Univ., Salt Lake City, UT, USA
  • Volume
    41
  • Issue
    3
  • fYear
    1999
  • fDate
    8/1/1999 12:00:00 AM
  • Firstpage
    234
  • Lastpage
    245
  • Abstract
    An automated specific absorption rate (SAR) measurement system has been developed for compliance testing of personal wireless devices. Unlike other systems, this system uses a model with a lossy ear-shaped protrusion and the accuracy of this experimental setup has been checked by comparing the peak 1-g SARs for ten cellular telephones, five each at 835 and 1900 MHz, with the results obtained using a 15-tissue anatomically based model with the finite-difference time-domain (FDTD) numerical electromagnetic technique. The SAR measurement system uses a three-dimensional (3-D) stepper motor to move a Narda Model 8021 E-field probe to measure the SAR distribution inside a head-shaped tissue-simulant phantom near the radiating device. The head and neck part of the model with an ear-shaped protrusion of 3 mm thickness is made of a lossy outer shell of 5-7 mm thickness of epoxy laced with KCl solution. The phantom is filled with appropriate frequency-specific fluids with measured electrical properties (dielectric constant and conductivity) that are close to the average for gray and white matters of the brain at the center frequencies of interest (835 and 1900 MHz). The implantable E-field probe is calibrated using the FDTD-calculated SAR variations for a slab model at two commonly used frequencies, 835 and 1900 MHz and is checked to have good isotropic characteristics (±0.23 dB) and a wide dynamic range (0.01-10 W/kg). The system is validated using a 223-mm-diameter sphere model. Peak 1-g SAR´s for ten telephones using different antennas are within ±1 dB of those obtained using the FDTD numerical method for the anatomical model of the head and neck region
  • Keywords
    biological effects of fields; brain; cellular radio; computerised instrumentation; electromagnetic fields; field strength measurement; finite difference time-domain analysis; safety; testing; 1900 MHz; 223 mm; 3 mm; 5 to 7 mm; 835 MHz; anatomical model; automated SAR measurement system; brain; cellular telephones; compliance testing; finite-difference time-domain analysis; implantable E-field probe; lossy ear-shaped protrusion; personal wireless devices; specific absorption rate; Automatic testing; Electromagnetic measurements; Electromagnetic modeling; Finite difference methods; Frequency; Imaging phantoms; Probes; System testing; Telephony; Time domain analysis;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/15.784158
  • Filename
    784158