Title :
Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring
Author :
Kim, Kyeong-Hwa
Author_Institution :
Dept. of Electr. Eng., Seoul Nat. Univ. of Sci. & Technol., Seoul, South Korea
Volume :
58
Issue :
6
fYear :
2011
fDate :
6/1/2011 12:00:00 AM
Firstpage :
2565
Lastpage :
2568
Abstract :
To detect a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor, a simple online fault detecting scheme is presented. The proposed scheme is based on the monitoring of the second-order harmonic components in the q-axis current through harmonic analysis. To verify the effectiveness of the proposed scheme, a test motor which allows an interturn short in the stator winding has been built, and the entire control system has been implemented using the DSP TMS320F28335.
Keywords :
digital control; fault diagnosis; machine control; permanent magnet motors; synchronous motors; DSP TMS320F28335; PMSM; control system; current harmonic monitoring; harmonic analysis; online fault detecting scheme; permanent magnet synchronous motor; q-axis current; second-order harmonic components; short-circuited turn; stator winding fault; test motor; Breakdown voltage; Control systems; Digital signal processing; Fault detection; Fault diagnosis; Harmonic analysis; Monitoring; Permanent magnet motors; Stator windings; Synchronous motors; Current harmonics; online fault diagnosis; permanent magnet synchronous motor (PMSM); stator turn fault;
fLanguage :
English