DocumentCode :
1550099
Title :
Estimation of dielectric loss using damped AC voltages
Author :
Houtepen, Richard ; Chmura, Lukasz ; Smit, Johan J. ; Quak, Ben ; Seitz, Paul P. ; Gulski, Edward
Author_Institution :
Delft Univ. of Technol., Delft, Netherlands
Volume :
27
Issue :
3
fYear :
2011
Firstpage :
20
Lastpage :
25
Abstract :
In this article some fundamental aspects of dielectric loss estimation using DAC voltage are described. Damped ac voltage testing is an alternative method of continuous ac voltage testing. It provides a method of assessing the condition of the insulation of capacitive test objects, e.g., power cables or stator windings of generators. The decay of damped ac voltages used for on-site energizing of power cables, and testing generator stator insulation, can be analyzed to estimate the dielectric loss (tan δ) of the insulation.
Keywords :
dielectric loss measurement; insulation testing; machine insulation; machine testing; power cable testing; stators; capacitive test object insulation; continuous ac voltage testing; damped ac voltage; dielectric loss estimation; generator stator insulation testing; power cables; AC motors; Dielectric loss measurement; Oil filled cables; Power cables; Stators; Voltage measurement; condition assessment; damped ac; dielectric loss; oil-impregnated insulation; on-site diagnostics; stator insulation;