• DocumentCode
    1556790
  • Title

    Discussion, with reply, of "A split-wound induction motor design to improve the reliability of PWM inverter drives" by J.C. Salmon and B.W. Williams

  • Author

    Powers, William ; Salmon, J.C.

  • Author_Institution
    Waterbed, CT, USA
  • Volume
    26
  • Issue
    6
  • fYear
    1990
  • Firstpage
    1006
  • Abstract
    With regard to the above-titled paper by J.C. Salmon and B.W. Williams (see ibid., vol.26, no.1, pt.1, p.143-50, 1990), the discusser points out that inverter drives featuring split-wound motors were marketed in 1971 by William Lear Enterprises, Inc. In reply, Salmon takes this opportunity to clarify some features of the inverter drive presented in his original paper. These features result in performance improvements over the standard unipolar inverter drive and the Lear inverter drive.<>
  • Keywords
    electric drives; induction motors; invertors; pulse width modulation; PWM inverter drives; William Lear Enterprises; performance improvements; reliability; split-wound induction motor; Circuit faults; Drives; Inductance; Induction motors; Power semiconductor switches; Protection; Pulse width modulation; Pulse width modulation inverters; Stator windings; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/28.62383
  • Filename
    62383