DocumentCode :
1558141
Title :
Night-Time EKG and HRV Monitoring With Bed Sheet Integrated Textile Electrodes
Author :
Peltokangas, M. ; Verho, J. ; Vehkaoja, A.
Author_Institution :
Dept. of Autom. Sci. & Eng., Tampere Univ. of Technol., Tampere, Finland
Volume :
16
Issue :
5
fYear :
2012
Firstpage :
935
Lastpage :
942
Abstract :
A system for unobtrusive night-time electrocardiogram (EKG) and heart rate variability (HRV) monitoring as well as data analysis methods are presented, comparing bed sheet HR and HRV values with corresponding parameters obtained by a reference measurement. Our system uses eight embroidered textile electrodes attached laterally to a bed sheet for measuring bipolar contact EKG from multiple channels. The electrodes are arranged in a line so that at least two adjacent electrodes make sufficient skin contact. The focus of the signal processing development has been on selecting the best measurement channel for further analysis and minimizing the amount of incorrectly detected R-peaks. The test measurements were performed with four healthy men without previously known cardiac disorders and one who frequently had premature ventricular contractions (ectopic beats). For healthy test subjects, an average of 94.9% heartbeat detection coverage was achieved with the system during 29 measurement nights (in total 213.8 h of data). In most cases, the quality of the signal obtained from bed sheet electrodes is good enough for the computer-assisted cardiac arrhythmia detection. Applications for EKG derived RR-interval data include the calculation of HRV parameters that can be utilized in sleep quality analysis and other wellness-related topics as well as sleep apnoea detection.
Keywords :
biomedical electrodes; biomedical measurement; electrocardiography; medical disorders; medical signal processing; patient monitoring; sleep; EKG; HRV monitoring; HRV parameters; R-peaks; RR-interval data; bed sheet integrated textile electrodes; bipolar contact EKG; computer-assisted cardiac arrhythmia detection; data analysis methods; ectopic beats; embroidered textile electrodes; heartbeat detection coverage; measurement channel; night-time ECG; premature ventricular contractions; reference measurement; signal processing; skin contact; sleep apnoea detection; sleep quality analysis; test measurements; time 213.8 h; unobtrusive night-time electrocardiogram; Electrocardiography; Electrodes; Heart rate variability; Noise; Sleep apnea; Night-time electrocardiogram (EKG, ECG); night-time heart rate variability (HRV); physiological monitoring; textile electrode; Adult; Beds; Electrocardiography; Electrodes; Female; Heart Rate; Humans; Male; Monitoring, Physiologic; Polysomnography; Signal Processing, Computer-Assisted; Textiles;
fLanguage :
English
Journal_Title :
Information Technology in Biomedicine, IEEE Transactions on
Publisher :
ieee
ISSN :
1089-7771
Type :
jour
DOI :
10.1109/TITB.2012.2208982
Filename :
6242411
Link To Document :
بازگشت