• DocumentCode
    1558968
  • Title

    Frequency response analysis and modeling of measurement transformers under distorted current and voltage supply

  • Author

    Samesima, M.I. ; de Oliveira, J.C. ; Dias, E.M.

  • Author_Institution
    Fed. Univ. of Uberlandia, Brazil
  • Volume
    6
  • Issue
    4
  • fYear
    1991
  • fDate
    10/1/1991 12:00:00 AM
  • Firstpage
    1762
  • Lastpage
    1768
  • Abstract
    The time and frequency response of current and potential transformers (CTs and PTs) operating under fundamental frequency conditions are well known. However, in the presence of harmonic frequencies, these transformers can exhibit significant errors. The authors present CT and PT comprehensive frequency domain equivalent circuits which, in addition to previous study features, include the hysteresis and eddy current effects. Furthermore, a practical approach which calculates the stray capacitances is proposed. By comparing theoretical and practical results the importance of considering parameters which are usually ignored in such studies is highlighted
  • Keywords
    current transformers; eddy currents; equivalent circuits; frequency response; frequency-domain analysis; harmonics; magnetic hysteresis; potential transformers; current transformers; distorted current supply; distorted voltage supply; eddy current effects; frequency domain equivalent circuits; frequency response; harmonic frequencies; hysteresis effects; measurement transformers; potential transformers; stray capacitances; time response; Capacitance; Circuit testing; Current measurement; Current transformers; Distortion measurement; Equivalent circuits; Frequency domain analysis; Frequency measurement; Frequency response; Voltage transformers;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.97718
  • Filename
    97718