DocumentCode
1560389
Title
Conducted and radiated interference measurements in the line-pantograph system
Author
Tellini, Bernardo ; Macucci, Massimo ; Giannetti, Romano ; Antonacci, Gabriele Alessandro
Author_Institution
Dipt. di Sistemi Elettrici a Automazione, Pisa Univ., Italy
Volume
50
Issue
6
fYear
2001
fDate
12/1/2001 12:00:00 AM
Firstpage
1661
Lastpage
1664
Abstract
We present the results of a measurement campaign aimed at investigating electromagnetic interference (EMI) phenomena in the interaction between overhead railway power supply lines and pantograph. In order to obtain such data, an experimental setup was assembled in a shielded room, consisting in a short section of overhead line and a full scale pantograph. One of the most interesting results consists in the observation of a very significant (both from the qualitative and the quantitative point of view) difference between the EMI behavior in the switch-on (pantograph going up) and switch-off (pantograph going down) transients
Keywords
electromagnetic interference; pantographs; power overhead lines; switching transients; conducted interference measurements; current waveforms; electric locomotives; electromagnetic compatibility; electromagnetic interference; line-pantograph system; lumped parameter model; overhead railway power supply lines; radiated interference measurements; switch-off transients; switch-on transients; time-domain measurements; voltage drop; Assembly; Contacts; Electromagnetic interference; Electromagnetic measurements; Electromagnetic radiation; Electromagnetic radiative interference; Electromagnetic shielding; Power measurement; Power supplies; Rail transportation;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.982964
Filename
982964