DocumentCode
1562906
Title
Performance results of 15 kW BIPV sunshade system
Author
Yu, G.J. ; So, J.H. ; Jung, Y.S. ; Kang, G.H. ; Choi, J.Y.
Author_Institution
Photovoltaic Syst. Res. Center, Korea Inst. of Energy Res., Taejon, South Korea
fYear
2005
Firstpage
1722
Lastpage
1725
Abstract
15 kW grid-connected building integrated photovoltaic (BIPV) sunshade system has been installed at Korea Institute of Energy Research (KIER) and monitoring system has also been constructed for measuring and analyzing performance of BIPV sunshade system to observe the overall effect of environmental conditions on their operation characteristics by long-term field test. Before installation of BIPV system, the performance of BIPV components such as power conditioning unit (PCU) and PV module under standard test conditions, which was measured and evaluated through short-term performance test. The performance of BIPV system has been evaluated and analyzed for component perspective (PV array and PCU) and global perspective (system efficiency, capacity factor, and electrical power energy, power quality etc.) for one year monitoring periods and loss factors are reviewed.
Keywords
building integrated photovoltaics; computerised monitoring; local area networks; power engineering computing; power system interconnection; 15 kW; BIPV sunshade system; Ethernet; TCP/IP; environmental conditions; grid-connected building integrated photovoltaic systems; monitoring system; power conditioning unit; Building integrated photovoltaics; Condition monitoring; Energy measurement; Measurement standards; Performance analysis; Performance loss; Power conditioning; Power measurement; Power quality; System testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Specialists Conference, 2005. Conference Record of the Thirty-first IEEE
ISSN
0160-8371
Print_ISBN
0-7803-8707-4
Type
conf
DOI
10.1109/PVSC.2005.1488481
Filename
1488481
Link To Document