DocumentCode :
1563083
Title :
Effects of short power interruptions and voltage sags on the performance of line start permanent magnet synchronous motor
Author :
Ugale, R.T. ; BalaKrishna, Y. ; Chaudhari, B.N.
Author_Institution :
Electr. Eng. Dept., Coll. of Eng., Pune
fYear :
2008
Firstpage :
184
Lastpage :
188
Abstract :
Line Start Permanent Magnet Synchronous motors are attracting growing attention for high duty factor industrial applications. Investigation of the performance of these motors under practical supply conditions facing power quality problems is the need of time. Voltage sags and short time interruptions contribute to 80% power quality related problems. In this paper, the behavior of this motor is studied under short power interruptions and voltage sag using dynamic model of the machine developed in Simulink platform.
Keywords :
permanent magnet motors; power supply quality; synchronous motors; high duty factor industrial applications; line start permanent magnet synchronous motor; power quality problems; short power interruptions; voltage sags; Line start permanent magnet synchronous motor; short power interruptions; voltage sag;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics, Machines and Drives, 2008. PEMD 2008. 4th IET Conference on
Conference_Location :
York
ISSN :
0537-9989
Print_ISBN :
978-0-86341-900-3
Type :
conf
Filename :
4528825
Link To Document :
بازگشت