• DocumentCode
    1563507
  • Title

    Losses in inductor-less piezoelectric transformer ballast for compact fluorescent lamps

  • Author

    Shafi, M.A. ; McMahon, Richard A. ; Weier, S.

  • Author_Institution
    Dept. of Eng., Cambridge Univ., Cambridge
  • fYear
    2008
  • Firstpage
    431
  • Lastpage
    435
  • Abstract
    In this study an inductor-less piezoelectric transformer (PT) based ballast for a 5 W CFL has been designed and simulated. The predictions of circuit currents and losses closely match experimentally measured values. The total simulated loss figure was confirmed against practically determined losses using a precision mini-calorimeter. Using simulation to disaggregate the total loss figure, it is seen that the PT makes the largest contribution to the total losses in such ballast.
  • Keywords
    calorimeters; fluorescent lamps; lamp accessories; power transformers; compact fluorescent lamps; inductor-less piezoelectric transformer ballast; mini-calorimeter; power 5 W; Ballast; calorimeter; fluorescent lamp; piezoelectric transformer;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics, Machines and Drives, 2008. PEMD 2008. 4th IET Conference on
  • Conference_Location
    York
  • ISSN
    0537-9989
  • Print_ISBN
    978-0-86341-900-3
  • Type

    conf

  • Filename
    4528875