DocumentCode
1563710
Title
Thermal performance of baseplate and direct substrate cooled power modules
Author
Skuriat, Robert ; Johnson, C.M.
Author_Institution
Nottingham Univ., Nottingham
fYear
2008
Firstpage
548
Lastpage
552
Abstract
In this paper a comparison of three coolers is presented: a coldplate onto which a conventional power module is mounted, a direct baseplate cooler and a direct substrate cooler. The direct baseplate and substrate coolers employed water jet impingement. By removing the baseplate the thermal resistance, mass and volume of the combined electronic package and cooler is reduced. At the same time potential improvements to reliability are realised through the removal of the bonded interface between the substrate and baseplate and the interface between the heat spreader and heat sink. For each cooler the heat transfer performance as a function pumping power was determined together with the transient thermal impedance. The effective heat transfer coefficient generated by the direct coolers (over 20 kW/m2K) was significantly higher than the coldplate (8 kW/m2K). Furthermore the total thermal resistance for the direct substrate cooler was lower than either the baseplate or coldplate cooled design variants, demonstrating that the heat transfer coefficient provided by jet impingement is high enough to obviate the need for a heat spreader plate. In addition the transient thermal impedance for the direct substrate cooler was substantially lower producing reduced levels of thermal cycling.
Keywords
cooling; modules; power electronics; thermal management (packaging); baseplate thermal performance; direct substrate cooled power modules; electronic package; heat transfer; thermal cycling; water jet impingement; Jet Impingement Direct Substrate Cooling;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives, 2008. PEMD 2008. 4th IET Conference on
Conference_Location
York
ISSN
0537-9989
Print_ISBN
978-0-86341-900-3
Type
conf
Filename
4528898