DocumentCode
1567813
Title
Investigation of Losses in Commercially Available Self-Resonant Ballasts for Compact Fluorescent Lamps
Author
Shafi, M.A. ; McMahon, R.A. ; Weier, S.
Author_Institution
Univ. of Cambridge, Cambridge
fYear
2007
Firstpage
3100
Lastpage
3105
Abstract
Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant electronic ballasts on grounds of cost. To improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a PSPICE model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioral model and the Jiles-Atherton equations were used to model the current transformer. The predicted loss is in close agreement with measurements from calorimetry, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation.
Keywords
calorimeters; calorimetry; fluorescent lamps; lamp accessories; Jiles-Atherton equations; PSPICE model; current transformer; integrated compact fluorescent lamps; precision minicalorimeter; self-resonant electronic ballasts; Electronic ballasts; Fluorescent lamps;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2007. PESC 2007. IEEE
Conference_Location
Orlando, FL
ISSN
0275-9306
Print_ISBN
978-1-4244-0654-8
Electronic_ISBN
0275-9306
Type
conf
DOI
10.1109/PESC.2007.4342521
Filename
4342521
Link To Document