• DocumentCode
    1569488
  • Title

    Employing the mathematical morphology algorithm with pseudo-optimal structure element for accurate partial discharge location in power cables

  • Author

    Soltani, A. ; Shahrtash, S.M.

  • Author_Institution
    Iran Univ. of Sci. & Technol. (IUST), Tehran, Iran
  • fYear
    2011
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    For accurate location of a partial discharge source in the power cables, exact determination of time of arrival of initiated waves by PD source, is very important. The proposed method in this paper is based on applying mathematical morphology operators to perform this task. In this method the Opening-Closing filter of mathematical morphology is used for noise reduction of signal and gradient operator is used for edge detection. The proposed method does not need to have any information about the load and the cable. Comparison with the published methods has shown higher accuracy of the proposed method. Moreover the effect of noise level, noise spectrum, pulse shape and load impedance on PD location accuracy are investigated.
  • Keywords
    edge detection; gradient methods; mathematical morphology; partial discharges; power cables; signal denoising; time-of-arrival estimation; edge detection; gradient operator; mathematical morphology algorithm; noise reduction; opening-closing filter; partial discharge location; power cables; pseudo-optimal structure element; Accuracy; Image edge detection; Morphology; Noise; Partial discharges; Power cables; Shape; Mathematical Morphology; PD location; cable; time of arrival;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Environment and Electrical Engineering (EEEIC), 2011 10th International Conference on
  • Conference_Location
    Rome
  • Print_ISBN
    978-1-4244-8779-0
  • Type

    conf

  • DOI
    10.1109/EEEIC.2011.5874583
  • Filename
    5874583