DocumentCode :
1569646
Title :
Single-pass induction motor parameter identification method taking into account saturation and rotor parameter variations
Author :
McKinnon, D.J. ; Grantham, C.
Author_Institution :
Hydro Tasmania Consulting, Cambridge, TAS, Australia
fYear :
2010
Firstpage :
1291
Lastpage :
1296
Abstract :
The paper describes a novel technique for on line parameter identification of three-phase induction motors from a single, run up to speed test. Data is sampled during this test with the normal locked rotor and synchronous speed data captured on the way to reaching the motor´s rated speed. Rotor parameter variations with frequency due to skin and proximity effects and other non linear imperfections such as heating and main flux path saturation are taken into account. This method is ideal for determining and/or verifying parameters used in high performance drives.
Keywords :
induction motors; parameter estimation; rotors; normal locked rotor; parameter identification method; rotor parameter variation; single pass induction motor; synchronous speed data; Current measurement; Electrical resistance measurement; Induction motors; Rotors; Stators; Temperature measurement; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2010 International Conference on
Conference_Location :
Incheon
Print_ISBN :
978-1-4244-7720-3
Type :
conf
Filename :
5664505
Link To Document :
بازگشت