DocumentCode :
157315
Title :
Detection of a short-circuit fault in the stator winding of induction motors through neighboring magnetic field harmonics
Author :
Fireteanu, V. ; Lombard, P. ; Constantin, A.I.
Author_Institution :
Politeh. Univ. of Bucharest, Bucharest, Romania
fYear :
2014
fDate :
2-5 Sept. 2014
Firstpage :
1555
Lastpage :
1561
Abstract :
This paper studies the influence on the magnetic field outside induction motors of a short-circuit fault in the stator winding through experimental investigations and time domain finite element analysis of the electromagnetic field. The detection of the stator short-circuit fault is the result of the comparison of amplitudes of particular harmonics of the output voltage of coil sensors placed around the motor, for the healthy and faulty motor states, for no-load and loaded motor operation. A detection system with two identical coil sensors ensures increased efficiency of fault detection and offers the possibility to identify the position of the faulty coil inside the motor.
Keywords :
coils; electromagnetic fields; fault diagnosis; finite element analysis; harmonic analysis; induction motors; magnetic fields; sensors; short-circuit currents; stators; time-domain analysis; amplitude comparison; coil sensor; electromagnetic field; faulty motor state; induction motor; loaded motor operation; neighboring magnetic field harmonics; no-load motor operation; short-circuit fault detection; stator winding; time domain finite element analysis; Circuit faults; Coils; Harmonic analysis; Induction motors; Magnetic fields; Sensors; Stator windings; Induction motors; coil sensors; fault detection; finite element analysis; output voltage harmonics; short-circuit in the stator winding;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2014 International Conference on
Conference_Location :
Berlin
Type :
conf
DOI :
10.1109/ICELMACH.2014.6960389
Filename :
6960389
Link To Document :