Abstract
This paper presents a comparison of the thermal properties between infiltrated and non-infiltrated copper windings. The focus is on thermal conductivity in the radial direction on the winding. The samples have a fill factor above 65 % due to the manufacturing method of the samples. Samples are produced and measured with the transient plane source technique and then compared to FEM simulations and the Hashin and Shtrikman approximation. The results show a considerable difference between a non-infiltrated and an infiltrated winding, as well as a good agreement between measurements, FEM simulations and the Hashin and Shtrikman approximation.
Keywords
approximation theory; copper; finite element analysis; machine windings; thermal conductivity; FEM simulation; Hashin approximation; Shtrikman approximation; high fill factor electrical winding; infiltrated copper winding; noninfiltrated copper winding; radial direction; thermal conductivity property; transient plane source technique; Conductivity; Heating; Materials; Thermal conductivity; Windings; Wires; Coils; Fill factor; Infiltrated; Non-infiltrated; Thermal analysis; Thermal conductivity; Winding;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines (ICEM), 2014 International Conference on
Conference_Location
Berlin
Type
conf
DOI
10.1109/ICELMACH.2014.6960492
Filename
6960492
Link To Document