• DocumentCode
    157417
  • Title

    Thermal properties on high fill factor electrical windings: Infiltrated vs non infiltrated

  • Author

    Siesing, L. ; Reinap, Avo ; Andersson, Mats

  • Author_Institution
    Div. of Production & Mater. Eng., Lund Univ., Lund, Sweden
  • fYear
    2014
  • fDate
    2-5 Sept. 2014
  • Firstpage
    2218
  • Lastpage
    2223
  • Abstract
    This paper presents a comparison of the thermal properties between infiltrated and non-infiltrated copper windings. The focus is on thermal conductivity in the radial direction on the winding. The samples have a fill factor above 65 % due to the manufacturing method of the samples. Samples are produced and measured with the transient plane source technique and then compared to FEM simulations and the Hashin and Shtrikman approximation. The results show a considerable difference between a non-infiltrated and an infiltrated winding, as well as a good agreement between measurements, FEM simulations and the Hashin and Shtrikman approximation.
  • Keywords
    approximation theory; copper; finite element analysis; machine windings; thermal conductivity; FEM simulation; Hashin approximation; Shtrikman approximation; high fill factor electrical winding; infiltrated copper winding; noninfiltrated copper winding; radial direction; thermal conductivity property; transient plane source technique; Conductivity; Heating; Materials; Thermal conductivity; Windings; Wires; Coils; Fill factor; Infiltrated; Non-infiltrated; Thermal analysis; Thermal conductivity; Winding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2014 International Conference on
  • Conference_Location
    Berlin
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2014.6960492
  • Filename
    6960492