DocumentCode
1579673
Title
Optimal matrix size for analysis of tissue engineering scaffold stiffness: A finite element study
Author
Chantarapanich, Nattapon ; Puttawibul, Puttisak ; Jeamwatthanachai, Pongnarin ; Sitthiseripratip, Kriskrai ; Sucharitpwatskul, Sedthawatt ; Laohaprapanon, Apinya
Author_Institution
Inst. of Biomed. Eng., Prince of Songkla Univ., Songkhla, Thailand
fYear
2012
Firstpage
104
Lastpage
107
Abstract
This study aimed to investigate the optimal matrix size of scaffold that response of smaller matrix is comparable to the response of the greater matrix, using finite element analysis. The analysis was based on the open-cellular truncated octahedron. Eight scaffold matrix sizes were evaluated which were lxlxl (single cell), 2×2×2 (8 cells), 3×3×3 (27 cells), 4×4×4 (64 cells), 5×5×5 (125 cells), 6×6×6 (216 cells), 7×7×7 (343 cells) and 8×8×8 (512 cells). From the result, it has revealed that smaller matrix exhibited the lower stiffness than the larger matrix. In addition, the percentage of relative change of scaffold stiffness was relatively steady at large matrix size. The conclusion can be drawn that the optimal matrix size was 6×6×6.
Keywords
biomedical materials; bone; cellular biophysics; finite element analysis; orthopaedics; tissue engineering; finite element analysis; open-cellular truncated octahedron; optimal matrix size; stiffness; tissue engineering scaffold; finite element analysis; matrix size; stiffness; tissue engineering scaffold;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Engineering International Conference (BMEiCON), 2011
Conference_Location
Chiang Mai
Print_ISBN
978-1-4577-2189-2
Type
conf
DOI
10.1109/BMEiCon.2012.6172029
Filename
6172029