• DocumentCode
    1581739
  • Title

    Study of method and system for diagnosis of cancer using autofluorescence and Raman spectroscopy

  • Author

    Xiaozhou Li ; Xingjia Guo ; Deli Wang ; Yue Wang ; Xinyu Li ; Ming Lei ; Junxiu Lin

  • Author_Institution
    Inst. of Appl. Phys., Dalian Univ. of Technol.
  • fYear
    2006
  • Firstpage
    5453
  • Lastpage
    5456
  • Abstract
    Laser-induced fluorescence (LIF) and Raman spectra were measured from normal and tumorous human serum in an attempt to discover some values useful in discrimination between normal and tumorous cases. Red shift of fluorescence peak and decrease of fluorescence intensity were observed after samples radiated by laser. According to one thousand twenty-two samples´ spectra, three parameters alpha, beta and Deltalambda are introduced to distinguish normal, benign and malignant from one another. The application of such parameters in clinical diagnosis was researched. The practical instrument of laser-induced serum fluorescence and resonance Raman spectra for cancer diagnosis or incipient cancer is designed, by combining laser spectroscopy, biomedical, photo-electron technology, controlling technology and computer technology. The instrument is intelligent for operating and diagnosing. The clinic application of this instrument has been carried out successfully in the diagnosing of stomach cancer and liver cancer (459 cases); the accuracy is about 85%. It develops a new technology in the field of cancer diagnosis
  • Keywords
    Raman spectra; cancer; fluorescence; laser applications in medicine; liver; patient diagnosis; red shift; tumours; Raman spectroscopy; autofluorescence; benign tumours; biomedical technology; cancer diagnosis; computer technology; controlling technology; laser spectroscopy; laser-induced serum fluorescence; liver cancer; malignant tumours; photo-electron technology; red shift; resonance Raman spectra; stomach cancer; tumorous human serum; Application software; Biomedical measurements; Cancer; Clinical diagnosis; Fluorescence; Humans; Instruments; Raman scattering; Resonance; Spectroscopy; LIF; Raman spectroscopy; cancer diagnosis; three parameters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-8741-4
  • Type

    conf

  • DOI
    10.1109/IEMBS.2005.1615717
  • Filename
    1615717