• DocumentCode
    1582315
  • Title

    Analytical minimal loss design of transformers for high frequency switch mode convertors

  • Author

    Callander, Graham ; Gardiner, Alister ; Johnson, Stephen

  • Author_Institution
    280 Pine Avenue, Christchurch, New Zealand
  • Issue
    0
  • fYear
    1995
  • Firstpage
    361
  • Abstract
    The transformer design philosophy presented is based on fundamental principles and facilitates the design of close to optimum transformers, without significant iteration. No new theoretical material is presented, but rather an analytical procedure that accords priority to minimising losses. The power transfer capacity of a transformer is constrained by its allowable operating temperature, a function of the power loss. A single total loss equation is derived consisting of core and winding components. The implicit assumptions are valid where skin depth and winding layers do not introduce significant proximity effect. A practical design example is included
  • Keywords
    Converters; Electrical equipment industry; Equations; Frequency conversion; Magnetic cores; Magnetic flux leakage; Magnetic separation; Switches; Transformer cores; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 1995. APEC '95. Conference Proceedings 1995., Tenth Annual
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2482-X
  • Type

    conf

  • DOI
    10.1109/APEC.1995.468974
  • Filename
    468974