• DocumentCode
    1582937
  • Title

    Computational investigation of operating conditions of the cascade generator MC-1 with large HE charge

  • Author

    Kozlov, M.B. ; Aseeva, V.V. ; Boriskov, G.V. ; Dolotenko, M.I. ; Rudenko, V.V. ; Shaburov, M.V.

  • Author_Institution
    Russian Fed. Nucl. Center-All-Russian Res. Inst. of Exp. Phys., Nizhny Novgorod, Russia
  • Volume
    2
  • fYear
    2001
  • Firstpage
    1182
  • Abstract
    VNIIEF is developing magnetocumulative generators of ultrahigh magnetic fields (MC-1) of various size, among which are generators with a large HE charge of 360 and 650 mm inner and outer diameter, and about 140 kg mass. Various sizes of the generator liners, their structural parameters and powering modes have been investigated using numerical model of the cascade MC-1 generator. The objective of the work is to choose a design and operating conditions for cascade MC-1 generator, which will provide maximal fields in a suitable for applications volume.
  • Keywords
    magnetic fields; numerical analysis; pulse generators; pulsed power supplies; 140 kg; 360 mm; 650 mm; cascade MC-1 generator; design conditions; generator liners; numerical model; operating conditions; powering modes; pulsed power generators; structural parameters; ultra-high magnetic field magnetocumulative generators; Costs; Helium; Magnetic fields; Nuclear power generation; Numerical models; Physics; Power generation; Pulse generation; Terminology; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Plasma Science, 2001. PPPS-2001. Digest of Technical Papers
  • Conference_Location
    Las Vegas, NV, USA
  • Print_ISBN
    0-7803-7120-8
  • Type

    conf

  • DOI
    10.1109/PPPS.2001.1001757
  • Filename
    1001757