DocumentCode
1584422
Title
A DC distribution demonstrator incorporating Active Impedance Estimation for marine applications
Author
Christopher, Edward ; Wang, Xiaohui ; Sumner, Mark ; Thomas, David ; Wang, Jing ; De Wildt, Lt Frans
Author_Institution
Dept. of Electr. & Electron. Eng., Univ. of Nottingham, Nottingham, UK
fYear
2010
Firstpage
1
Lastpage
5
Abstract
A small scale laboratory demonstrator has been constructed to represent a zonal DC distribution system as proposed for future naval vessels. This paper describes how the demonstrator has been used to validate a proposed fault location strategy - Active Impedance Estimation (AIE) - under experimental conditions. The practical processing algorithms required to reduce the effect of noise and the background supply harmonics are presented. The experimental results validate the AIE approach and confirm its robustness and accuracy.
Keywords
fault location; marine systems; power distribution faults; AIE approach; DC distribution demonstrator; active impedance estimation; background supply harmonic; fault location strategy; future naval vessels; marine application; practical processing algorithm; small scale laboratory demonstrator; zonal DC distribution system; Circuit faults; Continuous wavelet transforms; Estimation; Fault location; Harmonic analysis; Impedance; Transient analysis; DC distribution demonstrator; active impedance estimation; fault location; marine power system; protection;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Systems for Aircraft, Railway and Ship Propulsion (ESARS), 2010
Conference_Location
Bologna
Print_ISBN
978-1-4244-9092-9
Type
conf
DOI
10.1109/ESARS.2010.5665219
Filename
5665219