• DocumentCode
    1585177
  • Title

    Artificial pollution test and pollution performance of composite insulators

  • Author

    Xidong, Liang ; Shaowu, Wang ; Lengceng, Huang ; Qinghe, Shen ; Xueqi, Cheng

  • Author_Institution
    Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
  • Volume
    4
  • fYear
    1999
  • fDate
    6/21/1905 12:00:00 AM
  • Firstpage
    337
  • Abstract
    Based on the simulation of contaminant deposit, hydrophobicity status and wetting process in the laboratory, an artificial pollution test method suitable for composite insulators is recommended in this paper. It is found that hydrophobicity status and pollution level jointly determines composite insulator´s pollution performance. Neither of them can separately describe the overall pollution capability of the insulator. This suggests that composite insulators´ outdoor insulation evaluation in the field be achieved by regularly inspecting these two parameters
  • Keywords
    composite insulators; artificial pollution test; composite insulators; contaminant deposit simulation; hydrophobicity status; outdoor insulation evaluation; pollution level; pollution performance; wetting process;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-719-5
  • Type

    conf

  • DOI
    10.1049/cp:19990861
  • Filename
    821289