DocumentCode
1585177
Title
Artificial pollution test and pollution performance of composite insulators
Author
Xidong, Liang ; Shaowu, Wang ; Lengceng, Huang ; Qinghe, Shen ; Xueqi, Cheng
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
Volume
4
fYear
1999
fDate
6/21/1905 12:00:00 AM
Firstpage
337
Abstract
Based on the simulation of contaminant deposit, hydrophobicity status and wetting process in the laboratory, an artificial pollution test method suitable for composite insulators is recommended in this paper. It is found that hydrophobicity status and pollution level jointly determines composite insulator´s pollution performance. Neither of them can separately describe the overall pollution capability of the insulator. This suggests that composite insulators´ outdoor insulation evaluation in the field be achieved by regularly inspecting these two parameters
Keywords
composite insulators; artificial pollution test; composite insulators; contaminant deposit simulation; hydrophobicity status; outdoor insulation evaluation; pollution level; pollution performance; wetting process;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990861
Filename
821289
Link To Document