• DocumentCode
    1585634
  • Title

    Field test results of power-line signaling based anti-islanding scheme

  • Author

    Long, Xun ; Lerohl, Chris ; Xu, Wilsun ; Li, Yunwei ; Burr, Ken ; Senkow, Corey

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Alberta, Edmonton, AB, Canada
  • fYear
    2009
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The capability of anti-islanding protection is a very important requirement for distributed generators (DG). A power line signaling based scheme for anti-islanding protection has been proposed in a companion paper. In the scheme, a signal generated by power electronics is injected from a central upstream location to the DG sites. The lack of a signal at the DG site indicates that the DG is islanded. This paper is a summarization of extensive field test for the proposal. Two proposed detection algorithms have been verified, the impact of firing angles on signal strength have been determined and the effect of power system frequency drift have been analyzed. The test results proved that the proposed scheme is promising for the anti-islanding protection of distributed generator.
  • Keywords
    carrier transmission on power lines; power distribution protection; power system measurement; telecommunication signalling; anti islanding scheme; distributed generators; field test; firing angles; power electronics; power line signaling; power system frequency drift; Detection algorithms; Distributed power generation; Frequency; Power electronics; Power generation; Power system analysis computing; Power system protection; Proposals; Signal generators; Testing; Anti-Islanding; Distributed Generation; Power-Line Signaling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Power & Energy Conference (EPEC), 2009 IEEE
  • Conference_Location
    Montreal, QC
  • Print_ISBN
    978-1-4244-4508-0
  • Electronic_ISBN
    978-1-4244-4509-7
  • Type

    conf

  • DOI
    10.1109/EPEC.2009.5420811
  • Filename
    5420811