Title :
Fibre optic extensometer for high radiation and high temperature nuclear applications
Author :
Cheymol, G. ; Villard, J.F. ; Gusarov, A. ; Brichard, B.
Author_Institution :
Nucl. Energy Div., French Nucl. Energy Comm., Gif-sur-Yvette, France
Abstract :
In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation- sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400°C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10-2 i.e 5000με for an increase in temperature of 300-400°C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100μm (<; 1 μm error), at room temperature. The displacement measured can reach 250μm (20000με with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered.
Keywords :
Fabry-Perot interferometers; compaction; extensometers; fibre optic sensors; fission reactor core control; fission reactor design; fission reactor instrumentation; fission reactor materials; fission reactor safety; fission research reactors; gamma-ray effects; neutron effects; remote sensing; stainless steel; thermal stresses; BR2 MTR; Belgium; CEA; France; Joint Instrumentation Laboratory; SCK-CEN; Smirnof test facility; commercial fibre optic sensors; compact size; compaction effects; differential dilatation analysis; differential elongation; environment conditions; extrinsic Fabry Perot interferometer; gamma flux analysis; gamma heating process; gamma irradiation effect; gauge length; heavy neutron analysis; high irradiation field; high purity silica core; high radiation fibre optic extensometer; high resolution analysis; high temperature nuclear applications; interferometry; material testing reactor; mechanical stress; metal-coated fibre; neutron irradiation effect; pile irradiation effect; radiation-induced elongation measurement; remote sensing; room temperature; stainless steel; temperature 293 K to 298 K; thermal effect; thermal stress; wavelength 800 nm to 1200 nm; Inductors; Optical fibers; Radiation effects; Silicon compounds; Temperature measurement; Temperature sensors;
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2011 2nd International Conference on
Conference_Location :
Ghent
Print_ISBN :
978-1-4577-0925-8
DOI :
10.1109/ANIMMA.2011.6172876