Title :
External triggering of cold cathode thyratron in the system with blocking electrodes
Author :
Landl, N.V. ; Korolev, Y.D. ; Frants, O.B. ; Shemyakin, I.A. ; Geyman, V.G.
Author_Institution :
Inst. of High Current Electron., Tomsk, Russia
fDate :
Sept. 28 2014-Oct. 3 2014
Abstract :
One of the widely used systems for external triggering of the cold cathode thyratron (pseudospark switch) is based on a trigger unit with an auxiliary glow discharge. In most cases, the trigger unit is mounted at the grounded cathode. However, in some cases a specific requirement for triggering is demanded, namely, a trigger unit has to be located at potential cathode electrode. Direct application of the previous experience as applied to these cases leads to a rather intricate design for both mechanical parts of the trigger unit and electric circuit. This paper describes a simple trigger system for such conditions. Simultaneously with the function of external triggering, the system provides the so-called blocking effect, i.e. increasing a pulsed breakdown voltage and preventing the accident breakdowns in the regime of high pulse repetition rate.
Keywords :
cold-cathode tubes; electric breakdown; thyratrons; blocking effect; cold cathode thyratron; electric circuit; external triggering; pseudospark switch; pulsed breakdown voltage; Cathodes; Discharges (electric); Electric potential; Plasmas; Switches;
Conference_Titel :
Discharges and Electrical Insulation in Vacuum (ISDEIV), 2014 International Symposium on
Conference_Location :
Mumbai
Print_ISBN :
978-1-4799-6750-6
DOI :
10.1109/DEIV.2014.6961697