• DocumentCode
    1588868
  • Title

    Integrated test program for comparison of 10B lined proportional counting systems with 3He based counters for safeguards applications

  • Author

    Henzlova, Daniela ; Evans, Louise G. ; Menlove, Howard O. ; Swinhoe, Martyn T. ; Rael, Carlos D. ; Martinez, Isaac P. ; Marlow, Johnna B.

  • Author_Institution
    Safeguards Sci. & Technol. Group, Los Alamos Nat. Lab., Los Alamos, NM, USA
  • fYear
    2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    To address the urgent need to find a viable 3He replacement technology, Los Alamos National Laboratory has developed an integrated test program for performance evaluation of 3He replacement technologies with focus on safeguards specific parameters. In addition, a dedicated experimental setup was built to support the experimental activities. Current activity focuses on evaluation of 10B lined proportional counters. This paper presents an overview of the test program as well as the first results from the GE/Reuter-Stokes 10B lined system.
  • Keywords
    helium-3 counters; 10B lined proportional counting systems; 3He based counters; GE 10B lined system; Los Alamos National Laboratory; Reuter-Stokes 10B lined system; integrated test program; safeguard specific parameters; viable 3He replacement technology; Benchmark testing; Detectors; Electron tubes; Face; Neutrons; Radiation detectors; Slabs;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2011 2nd International Conference on
  • Conference_Location
    Ghent
  • Print_ISBN
    978-1-4577-0925-8
  • Type

    conf

  • DOI
    10.1109/ANIMMA.2011.6172938
  • Filename
    6172938