• DocumentCode
    158944
  • Title

    H.V. support structure of 3MVDC generator and its protection from HV discharges in vacuum and SF6 gas for DC electron Accelerator

  • Author

    Sharma, D.K. ; Rajan, R.N. ; Srivastava, S.K. ; Dewangan, S. ; Jayaprakash, D. ; Bakhtsingh, R.I. ; Acharya, Sanjeev ; Gantayet, L.M.

  • Author_Institution
    Accel. & Pulse Power Div., Bhabha Atomic Res. Centre, Mumbai, India
  • fYear
    2014
  • fDate
    Sept. 28 2014-Oct. 3 2014
  • Firstpage
    649
  • Lastpage
    651
  • Abstract
    Accelerator and Pulse Power Division of BARC has developed a DC electron accelerator for cross linking of polymers, medical starilisation, preservation of food. The demonstration of stack-gas cleanup for green power generation has been demonstrated successfully. The support structure of the 3MVDC voltage generator is made of Perspex for high dielectric strength, easy availability of raw material, excellent radiation resistance and long term dimensional stability. This paper describes the salient design features of the High voltage support structure in brief.
  • Keywords
    discharges (electric); electron accelerators; 3MVDC generator; BARC; DC electron accelerator; HV discharges; High voltage support structure; Perspex; Pulse Power Division; SF6 gas; green power generation; high dielectric strength; medical starilisation; radiation resistance; stack-gas cleanup; vacuum; Acceleration; Corona; Discharges (electric); Electrodes; Electron tubes; Rectifiers; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Discharges and Electrical Insulation in Vacuum (ISDEIV), 2014 International Symposium on
  • Conference_Location
    Mumbai
  • Print_ISBN
    978-1-4799-6750-6
  • Type

    conf

  • DOI
    10.1109/DEIV.2014.6961766
  • Filename
    6961766