DocumentCode
158944
Title
H.V. support structure of 3MVDC generator and its protection from HV discharges in vacuum and SF6 gas for DC electron Accelerator
Author
Sharma, D.K. ; Rajan, R.N. ; Srivastava, S.K. ; Dewangan, S. ; Jayaprakash, D. ; Bakhtsingh, R.I. ; Acharya, Sanjeev ; Gantayet, L.M.
Author_Institution
Accel. & Pulse Power Div., Bhabha Atomic Res. Centre, Mumbai, India
fYear
2014
fDate
Sept. 28 2014-Oct. 3 2014
Firstpage
649
Lastpage
651
Abstract
Accelerator and Pulse Power Division of BARC has developed a DC electron accelerator for cross linking of polymers, medical starilisation, preservation of food. The demonstration of stack-gas cleanup for green power generation has been demonstrated successfully. The support structure of the 3MVDC voltage generator is made of Perspex for high dielectric strength, easy availability of raw material, excellent radiation resistance and long term dimensional stability. This paper describes the salient design features of the High voltage support structure in brief.
Keywords
discharges (electric); electron accelerators; 3MVDC generator; BARC; DC electron accelerator; HV discharges; High voltage support structure; Perspex; Pulse Power Division; SF6 gas; green power generation; high dielectric strength; medical starilisation; radiation resistance; stack-gas cleanup; vacuum; Acceleration; Corona; Discharges (electric); Electrodes; Electron tubes; Rectifiers; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Discharges and Electrical Insulation in Vacuum (ISDEIV), 2014 International Symposium on
Conference_Location
Mumbai
Print_ISBN
978-1-4799-6750-6
Type
conf
DOI
10.1109/DEIV.2014.6961766
Filename
6961766
Link To Document