DocumentCode
1590481
Title
An efficient time-domain approach based on Prony´s method for time-varying power system harmonics estimation
Author
Chen, C.I. ; Chang, G.W.
Author_Institution
Dept. of Electr. Eng., Nat. Chung Cheng Univ., Chiayi, Taiwan
fYear
2009
Firstpage
1
Lastpage
6
Abstract
In this paper an efficient time-domain technique based on Prony´s method for the time-varying power system harmonics estimation is proposed. Though the high frequency resolution is the major advantage of Prony´s method, the great computational burden with the high estimation order usually makes it only suitable for the off-line analysis. To achieve the fast harmonic measurement, a filter-bank structure is proposed to reduce the computational complexity. Finally, the measurement results are reported to verify the performance of the proposed technique.
Keywords
function approximation; parameter estimation; power harmonic filters; power system harmonics; time-domain analysis; time-varying systems; Prony method; computational complexity; filter bank structure; harmonic measurement; time domain method; time varying power system harmonics estimation; Discrete Fourier transforms; Frequency estimation; Frequency synchronization; Interpolation; Power harmonic filters; Power system analysis computing; Power system harmonics; Signal analysis; Time domain analysis; Time varying systems; Prony´s method; filter-bank structure; root-finding; time-varying power system harmonic;
fLanguage
English
Publisher
ieee
Conference_Titel
Power & Energy Society General Meeting, 2009. PES '09. IEEE
Conference_Location
Calgary, AB
ISSN
1944-9925
Print_ISBN
978-1-4244-4241-6
Type
conf
DOI
10.1109/PES.2009.5275761
Filename
5275761