    Interferential current stimulation for sensory communication between prosthetic hand and man

  • Author

    Nomura, Kunihiko ; Yada, Keita ; Saihara, Masafumi ; Yoshida, Masaki

  • Author_Institution
    Dept. of Biomed. Eng., Osaka Electro-Commun. Univ.
  • fYear
    2006
  • Firstpage
    6923
  • Lastpage
    6926
  • Abstract
    Our purpose is to clear whether the interferential current (IFC) method is useful for information transmission of a myoelectric prosthetic hand to the user. IFC stimulation is composed of two AC output waves. Previously, we demonstrated that IFC method using the two waves with different frequencies could vary the intensity of perceived stimulus. In the present study, we evaluated that the relationship between a movement of position of perceived stimulus and IFC method, using two waves with the same median frequency and a different phase. Moreover, we investigated the effects of a distance of recording electrodes from stimulating electrodes on a degree of interference of IFC with EMG signals. The movement of position of perceived stimulus was caused by the phase difference changing. IFC interfered with EMG signals. Especially, the interference of IFC with EMG of the muscle under stimulating electrodes was large. In contrast, when recording electrodes was distant from the stimulating electrodes, the interference of IFC was small. Moreover, the interference was eliminated by the low-pass filter (< 500Hz). These results support the usefulness of a combination of the IFC method with EMG recording system equipped with the low-pass filter as a sensory feedback system for myoelectric prosthetic hand
  • Keywords
    biomedical electrodes; electromyography; feedback; low-pass filters; medical control systems; prosthetics; EMG signals; interferential current stimulation; low-pass filter; myoelectric prosthetic hand; phase difference; recording electrodes; sensory communication; sensory feedback system; stimulating electrodes; Biomedical engineering; Control systems; Electrodes; Electromyography; Frequency; Impedance; Interference elimination; Low pass filters; Prosthetic hand; Skin;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-8741-4
  • Type

    conf

  • DOI
    10.1109/IEMBS.2005.1616098
  • Filename
    1616098