  • Abstract
    Minimum input sample size and thickness for SELA MC600, a micro-cleaving tool, is 9 × 6 mm and 0.6 mm respectively. The machine will reject sample which is smaller or thinner than this acceptance value. But, in semiconductor Failure Analysis (FA) laboratories, it is inevitable to face such small and thin sample, for instance, a die from backgrinded wafer. Therefore, a technique named Dual-Edged Cleaving (DEC) is invented to circumvent this restriction.
  • Keywords
    micromechanical devices; semiconductor device models; DEC; SELA MC600 microcleaving tool; backgrinded wafer; dual-edged cleaving; input sample acceptance; semiconductor failure analysis laboratory; Costs; Crystalline materials; Failure analysis; Ion beams; Laboratories; Milling; Optical microscopy; Particle beam optics; Silicon; Surface cleaning;