• DocumentCode
    1593874
  • Title

    The influence of air gap size and winding position on the proximity losses in high frequency transformers

  • Author

    Albach, Manfred ; Rossmanith, H.

  • Author_Institution
    Lehrstuhl fur Elektromagnetische Felder, Friedrich-Alexander-Universitat, Erlangen, Germany
  • Volume
    3
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1485
  • Abstract
    The proximity losses in high-frequency transformers strongly depend on size and position of the air gaps as well as on the position of the turns inside the winding area. This paper demonstrates the analytical calculation of the two-dimensional field distribution, which is needed for the accurate calculation of these losses
  • Keywords
    electric fields; high-frequency transformers; losses; transformer windings; air gap position; air gap size; high frequency transformers; losses calculation; proximity losses; turns position; two-dimensional field distribution; winding position; Air gaps; Boundary value problems; Ferrites; Frequency; Magnetic analysis; Magnetic cores; Magnetic fields; Permeability; Transformers; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2001. PESC. 2001 IEEE 32nd Annual
  • Conference_Location
    Vancouver, BC
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-7067-8
  • Type

    conf

  • DOI
    10.1109/PESC.2001.954329
  • Filename
    954329