• DocumentCode
    1593954
  • Title

    Large generator vibration monitoring

  • Author

    Fortin, T. ; Duffeau, F.

  • Author_Institution
    Electr. de France, Paris, France
  • fYear
    1997
  • Firstpage
    155
  • Lastpage
    159
  • Abstract
    Two major generator incidents have resulted in unplanned and extensive outages in French nuclear power plants. A large action was launched to prevent this kind of incident. One part of this programme is improving on-line generator vibration monitoring. As far as the EDF Research and Development Division is concerned, the aim was to define end-winding stator vibration monitoring. Today, EDF nuclear power plants are equipped with on-line stator end-winding vibration monitoring. Previous studies, undertaken in EDF, enabled optimisation of the number and, above all, the location of sensors. The first goal of this monitoring is the protection of the machine, in order to avoid critical failure. But, the database which was created makes it possible to develop new methods, using vibration measurements, which are really interesting. So, the method described is a powerful tool to anticipate and to plan operation and maintenance actions. The on-line stator vibration monitoring is no more only a protection device but also a maintenance optimisation tool
  • Keywords
    stators; EDF; French nuclear power plants; generator protection; generator vibration monitoring; maintenance optimisation tool; maintenance planning; on-line generator vibration monitoring; stator end-winding vibration monitoring;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
  • Conference_Location
    Cambridge
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-696-2
  • Type

    conf

  • DOI
    10.1049/cp:19971058
  • Filename
    677079