DocumentCode
159546
Title
Continuous wearable health monitoring using novel PPG optical sensor and device
Author
Mouradian, Vahram ; Poghosyan, Armen ; Hovhannisyan, Levon
Author_Institution
Sensogram Technol. Inc., Plano, TX, USA
fYear
2014
fDate
8-10 Oct. 2014
Firstpage
120
Lastpage
123
Abstract
We are presenting a novel photoplethysmographic (PPG) optical sensor and device with ambient optical, electrical and electromagnetic noises cancellation, thus allowing only the useful optical signals to be received by the health monitoring device. We are also disclosing a new processing technique for canceling the ambient noises contributed by optical, electrical and electromagnetic artifacts in the measured PPG signals. Such a device and method allow the enhancement of the performance of the PPG sensors compared to conventional apparatus and methods. The presented sensor and methodology have been integrated into a prototype device for noninvasive, continuous, wearable, remote and mobile monitoring of human vital signs, such as heart rate, oxygen saturation, blood pressure, respiration rate, etc. This small device allows the user to read, store, process and transmit all the measurements made using the PPG optical sensor and the electronic unit to a remote location.
Keywords
biochemistry; biomedical telemetry; blood pressure measurement; body sensor networks; cardiology; electronic data interchange; information storage; medical signal processing; mobile computing; optical noise; optical sensors; oxygen; patient monitoring; photoplethysmography; pneumodynamics; prototypes; signal denoising; telemedicine; O2; PPG optical sensor; PPG sensor performance enhancement; ambient electrical noise cancellation; ambient electromagnetic noise cancellation; ambient optical noise cancellation; blood pressure monitoring; continuous wearable health monitoring; electrical artifact; electromagnetic artifact; electronic unit; health monitoring device; heart rate monitoring; human vital sign monitoring; measurement processing; measurement reading; measurement storage; measurement transmission; mobile monitoring; noninvasive monitoring; optical artifact; oxygen saturation monitoring; photoplethysmographic device; processing technique; prototype device; remote monitoring; respiration rate monitoring; Biomedical monitoring; Blood; Monitoring; Noise; Optical sensors; Optical variables measurement; PPG sensor; mobile health; photoplethysmography; wearable health monitoring device;
fLanguage
English
Publisher
ieee
Conference_Titel
Wireless and Mobile Computing, Networking and Communications (WiMob), 2014 IEEE 10th International Conference on
Conference_Location
Larnaca
Type
conf
DOI
10.1109/WiMOB.2014.6962159
Filename
6962159
Link To Document