DocumentCode
1595482
Title
Condition monitoring of inverter fed induction machines by means of state variable observation
Author
Wieser, Rudolf ; Kral, Christian ; Pirker, Franz ; Schagginger, Matthias
Author_Institution
Vienna Univ. of Technol., Austria
fYear
1997
Firstpage
336
Lastpage
340
Abstract
This paper suggests a method to monitor defects such as cracked rotor bars in induction machines. Rotor bar faults cause an asymmetric magnetic flux pattern in the air-gap. Thus, the current phasor (or voltage phasor at current controlled machines), the flux phasor and the air-gap torque differ from those of an ideal symmetric machine. The proposed condition monitoring method compares the outputs of a reference model that represents an ideal machine to a measurement model. Observing the deviations of these two models makes it possible to detect and even locate rotor faults. It can be applied to inverter fed machines as no frequency analysis is used. The method is verified by experimental results from a DSP-controlled IGBT-inverter drive
Keywords
asynchronous machines; IGBT-invertors; air-gap torque; condition monitoring method; cracked rotor bars; current phasor; flux phasor; induction machines; rotor bar fault monitoring; state variable observation; voltage phasor;
fLanguage
English
Publisher
iet
Conference_Titel
Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
Conference_Location
Cambridge
ISSN
0537-9989
Print_ISBN
0-85296-696-2
Type
conf
DOI
10.1049/cp:19971094
Filename
677142
Link To Document