• DocumentCode
    1595482
  • Title

    Condition monitoring of inverter fed induction machines by means of state variable observation

  • Author

    Wieser, Rudolf ; Kral, Christian ; Pirker, Franz ; Schagginger, Matthias

  • Author_Institution
    Vienna Univ. of Technol., Austria
  • fYear
    1997
  • Firstpage
    336
  • Lastpage
    340
  • Abstract
    This paper suggests a method to monitor defects such as cracked rotor bars in induction machines. Rotor bar faults cause an asymmetric magnetic flux pattern in the air-gap. Thus, the current phasor (or voltage phasor at current controlled machines), the flux phasor and the air-gap torque differ from those of an ideal symmetric machine. The proposed condition monitoring method compares the outputs of a reference model that represents an ideal machine to a measurement model. Observing the deviations of these two models makes it possible to detect and even locate rotor faults. It can be applied to inverter fed machines as no frequency analysis is used. The method is verified by experimental results from a DSP-controlled IGBT-inverter drive
  • Keywords
    asynchronous machines; IGBT-invertors; air-gap torque; condition monitoring method; cracked rotor bars; current phasor; flux phasor; induction machines; rotor bar fault monitoring; state variable observation; voltage phasor;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
  • Conference_Location
    Cambridge
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-696-2
  • Type

    conf

  • DOI
    10.1049/cp:19971094
  • Filename
    677142