• DocumentCode
    1595523
  • Title

    Supply invariant induction machine condition monitoring

  • Author

    Arthur, N. ; Penman, J.

  • Author_Institution
    Aberdeen Univ., UK
  • fYear
    1997
  • Firstpage
    341
  • Lastpage
    345
  • Abstract
    This paper examines the use of third-order statistical measures as an induction machine condition monitoring tool. It is demonstrated that these third-order measures improve on traditional fault detection techniques and unambiguously detect single and combined fault conditions in an induction machine fed from fixed and variable frequency supplies
  • Keywords
    asynchronous machines; combined fault conditions detection; condition monitoring tool; fault detection techniques; induction machine; single fault conditions detection; third-order statistical measures;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
  • Conference_Location
    Cambridge
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-696-2
  • Type

    conf

  • DOI
    10.1049/cp:19971095
  • Filename
    677143