DocumentCode :
1596148
Title :
Atmospheric pressure microwave-powered microplasma source based on strip-line structure
Author :
Liu, Peng ; Grotjohn, Timothy A.
Author_Institution :
Electr. & Comput. Eng., Michigan State Univ., East Lansing, MI, USA
fYear :
2013
Firstpage :
1
Lastpage :
1
Abstract :
Summary form only given. Portable low cost microplasma sources are of interest for various applications such as materials processing, treatment of biomedical materials, chemical analysis and optical radiation sources. Microplasma sources are especially of interest for atmospheric pressure operation because they do not require a vacuum system. Further, by using higher frequency energy (microwave) to power the microplasma discharge, erosion of electrodes is reduced or essentially eliminated. Another feature of microplasmas is the high power density and plasma density of the discharges. Additionally, the gas temperature of microdischarges is lower than larger plasmas at atmospheric pressure. In this investigation a microwave powered microplasma system based on a double-strip-line structure is developed for the generation of atmospheric pressure plasmas with various feed-gases and feed-gas mixtures. The microplasma system is constructed with the top and bottom copper strip-lines separated by a dielectric material. The strip-line structure is powered at one end and the plasma is formed at the other end where the two copper strip-lines are brought together to a gap with 250 microns separation. The feed-gas is flowed through a channel in the dielectric such that it exits with the feed-gas flowing into the gap created by the two strip-lines. The gas flow channel in the dielectric is 250 microns high by 6 mm wide. The flow rate is varied from 900-2400 sccm. Argon and argon-oxygen microplasma discharges are formed in the gap between the two copper strip-lines. In argon-oxygen plasmas investigated, the oxygen percentage is varied from 1% up to 5%. The microwave power used for the discharges varies from 5 to 60 Watts. Images of the plasma are taken to show the shape, volume and intensity of the microplasmas. Optical emission spectroscopy is used to diagnose the discharges. The emissions from selected excited atomic and molecular oxygen species are measured. Other properties of- the microplasma including gas temperature and electron temperature are also measured. Some experiments of etching diamond with argon-oxygen microdischarges will be presented.
Keywords :
argon; biomedical materials; channel flow; high-frequency discharges; oxygen; plasma density; plasma diagnostics; plasma flow; plasma materials processing; plasma sources; plasma temperature; Ar; Ar-O2; O2; argon microplasma discharge; argon-oxygen microplasma discharge; atmospheric pressure microwave-powered microplasma source; atmospheric pressure operation; biomedical material treatment; bottom copper strip-lines; chemical analysis; dielectric material; distance 250 micron; double-strip-line structure; electrode erosion; electron temperature; etching diamond; excited atomic oxygen species; feed-gas flow; feed-gas mixtures; flow rate; gas flow channel; high frequency energy; high power density; materials processing; microdischarge gas temperature; microplasma intensity; microplasma shape; microplasma volume; molecular oxygen species; optical emission spectroscopy; optical radiation sources; oxygen percentage; plasma density; portable low cost microplasma sources; power 5 W to 60 W; pressure 1 atm; size 6 mm; top copper strip-lines; vacuum system; Copper; Discharges (electric); Microwave imaging; Optical imaging; Plasma temperature; Temperature measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
Conference_Location :
San Francisco, CA
ISSN :
0730-9244
Type :
conf
DOI :
10.1109/PLASMA.2013.6634979
Filename :
6634979
Link To Document :
بازگشت