    Study on the Measurement Method of Leakage Flow-rate for Pneumatic Driving Apparatus

  • Author

    Jang, Ji-Seong ; Ji, Sang-Won ; Kang, Bo-Sik

  • Author_Institution
    Fac. of Eng., Pukyong Nat. Univ., Pusan
  • fYear
    2006
  • Firstpage
    4116
  • Lastpage
    4120
  • Abstract
    In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there was no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured by the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic apparatus. The effectiveness of the proposed method is proved by experimental results
  • Keywords
    flow measurement; leak detection; life testing; pneumatic systems; test equipment; isothermal chamber; isothermal conditions; leakage flow-rate measurement; life testing; pneumatic driving apparatus; pressure change; steel wool; test component; Engine cylinders; Isothermal processes; Life testing; Mechanical variables measurement; Particle measurements; Pistons; Pressure measurement; Steel; Temperature; Wool; Leakage Flow-rate; Life Test; Pneumatic Apparatus;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE-ICASE, 2006. International Joint Conference
  • Conference_Location
    Busan
  • Print_ISBN
    89-950038-4-7
  • Electronic_ISBN
    89-950038-5-5
  • Type

    conf

  • DOI
    10.1109/SICE.2006.315157
  • Filename
    4108230