DocumentCode
1602429
Title
Accurate modeling of open-ended coaxial sensor by non-uniform FDTD method
Author
Jobava, R. ; Gheonjian, A.
Author_Institution
Lab. of Appl. Electrodynamics, Tbilisi State Univ., Georgia
fYear
1999
fDate
6/21/1905 12:00:00 AM
Firstpage
101
Lastpage
104
Abstract
The open-ended coaxial sensor is modeled by a non-uniform FDTD method. Such sensors are used for complex permittivity measurements in the MHz-GHz frequency range. The accuracy of the measurements depend greatly on the accuracy of the reflection coefficient computation. The non-uniform grid makes it possible to use very fine discretization in the critical area where the open-end of the coax is attached to the sample. The method can be used to calculate the reflection coefficient for very thin samples
Keywords
coaxial cables; electric sensing devices; electromagnetic wave reflection; finite difference time-domain analysis; permittivity measurement; accurate modeling; coaxial line; complex permittivity measurement; measurement accuracy; nonuniform FDTD method; open-ended coaxial sensor; reflection coefficient; very thin samples; Coaxial components; Dielectric losses; Dielectric measurements; Finite difference methods; Geometry; Integral equations; Lattices; Permittivity measurement; Reflection; Time domain analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Direct and Inverse Problems of Electromagnetic and Acoustic Wave Theory, 1999. Proceedings of IVth International Seminar/Workshop
Conference_Location
Lviv
Print_ISBN
966-02-0864-2
Type
conf
DOI
10.1109/DIPED.1999.822138
Filename
822138
Link To Document