DocumentCode
1604476
Title
Improved INFORM method by minimizing the inverter nonlinear voltage error effects
Author
Ge Xie ; Kaiyuan Lu ; Dwivedi, Sanjeet Kumar ; Rosholm, Jesper Riber
Author_Institution
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
fYear
2015
Firstpage
188
Lastpage
194
Abstract
The INFORM (Indirect Flux detection by Online Reactance Measurements) method is regularly used for estimating the rotor position in PMSM sensorless drive systems at low speed and standstill. However, the estimation accuracy of the rotor position highly depends on how accurately the desired injection voltage vector may be produced. In this paper, a new method for generating the desired injection voltage vector is proposed. The nonlinear voltage error will be limited to one phase only, allowing an easy compensation. The performance of the INFORM method with the proposed voltage injection method is demonstrated experimentally. Comparison to the traditional voltage vector generation method is given as well.
Keywords
invertors; permanent magnet motors; sensorless machine control; synchronous motor drives; INFORM method; PMSM sensorless drive systems; indirect flux detection by online reactance measurement method; injection voltage vector; inverter nonlinear voltage error effects minimization; nonlinear voltage error; rotor position estimation; voltage vector generation method; Estimation; Inverters; Rotors; Space vector pulse width modulation; Stators; Voltage control; Voltage measurement; INFORM; PMSM; Sensorless control; inverter voltage error; low speed;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines Design, Control and Diagnosis (WEMDCD), 2015 IEEE Workshop on
Conference_Location
Torino
Type
conf
DOI
10.1109/WEMDCD.2015.7194528
Filename
7194528
Link To Document