DocumentCode :
1605560
Title :
ECG signal compression by using multiquadric interpolation
Author :
Boonyaves, P. ; Paisalsing, P. ; Totarong, P. ; Jitapunkul, S.
Author_Institution :
Dept. of Electr. Eng., Chulalongkorn Univ., Bangkok, Thailand
Volume :
2
fYear :
2004
Firstpage :
947
Abstract :
ECG signals are used to diagnose heart disease with exercise stress testing, no risk method. The mathematical models are used to compress data of ECG signals for storage and transmission. And parameters obtained from compression can be used to reconstruct an ECG signal which is without clinical information loss for diagnosis later. In this paper the multiquadric interpolation method (MQ) is proposed to compress the ECG signals. The compression ratio of the reconstructed signals is about 7 and the percent root mean square difference (PRD) is about 6 percent.
Keywords :
data compression; diseases; electrocardiography; interpolation; medical signal processing; signal reconstruction; ECG signal compression; data storage; heart disease diagnosis; multiquadric interpolation; percent root mean square difference; signal reconstruction; Cardiac disease; Differential equations; Digital signal processing; Electrocardiography; Geology; Interpolation; Mathematical model; Metrology; Stress; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 2004. Canadian Conference on
ISSN :
0840-7789
Print_ISBN :
0-7803-8253-6
Type :
conf
DOI :
10.1109/CCECE.2004.1345272