Abstract :
This study investigates the possibility of using the normalized time-domain features of electrocardiogram (ECG) for improving the capability of human identification. For this purpose, we measured lead-1 rest ECG (normal heart rate) and physically active one (fast heart rate) from the pre-selected group. The characteristic points on the ECG waveform, P, QRS, T are extracted in terms of its time location and the ECG data is reconstructed in beat-by-beat basis by Fourier synthesis. R-T interval, Q-T interval, and QRS interval on the reconstructed ECG sequence in rest and in physical active mode are computed. The beat-by-beat based discriminatory analysis is performed on the rest and physical active ECG data by applying Malalanobis´ distance between these intervals
Keywords :
Fourier series; electrocardiography; medical signal processing; signal reconstruction; time-domain analysis; ECG; ECG sequence; Fourier synthesis; Malalanobis distance; P waveform; Q-T interval; QRS interval; R-T interval; beat-by-beat based discriminatory analysis; electrocardiogram; fast heart rate; normal heart rate; normalized time-domain features; robust human identification; signal reconstruction; time location; Biomedical engineering; Biomedical measurements; Data mining; Electrocardiography; Heart rate; Humans; Performance analysis; Physics computing; Robustness; Time domain analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1616615
Filename :
1616615
Link To Document :
بازگشت