DocumentCode :
1608518
Title :
Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard
Author :
Wu, R.H. ; Lin, R. ; Li, H. ; Xiao, Z.W. ; Rao, H.B. ; Luo, W.H. ; Guo, G. ; Huang, K. ; Zhang, X.G. ; Lang, Z.J.
Author_Institution :
Med. Imaging & Central Lab., Shantou Univ. Med. Coll.
fYear :
2006
Firstpage :
1396
Lastpage :
1399
Abstract :
The metabolite ratios had been employed in the field of MR spectroscopy (MRS) for a long period. The main drawback of metabolite ratio is that ratio results are not comparable with absolute metabolite concentration in vivo. The purpose of this study was to examine the accuracy of noninvasive quantification of brain N-acetylaspartate (NAA) concentrations using previously reported MR external standard method. Eight swine were scanned on a GE 1.5 T scanner with a standard head coil. The external standard method was utilized with a sphere filled with NAA, GABA, glutamine, glutamate, creatine, choline chloride, and myo-inositol. The position resolved spectroscopy (PRESS) sequence was used with TE=135 msec, TR=1500 msec, and 128 scan averages. The analysis of MRS was done with SAGE/IDL program. In vivo NAA concentration was obtained using the equation S=N * e(-TE/T2) * [1-e(-TR/T1). In vitro NAA concentration was measured by high performance liquid chromatography (HPLC). In the MRS group, the mean concentration of NAA was 10.03 plusmn 0.74 mmol/kg. In the HPLC group, the mean concentration of NAA was 9.22 plusmn 0.55 mmol/kg. There was no significant difference between the two groups (p = 0.46). However, slightly higher value was observed in the MRS group (7/8 swine), compared with HPLC group. The range of differences was between 0.02~2.05 mmol/kg. MRS external reference method could be more accurate than internal reference method. 1H MRS does not distinguish between N-acetyl resonance frequencies and other N-acetylated amino acids
Keywords :
biomedical NMR; brain; chromatography; 1.5 T; 135 ms; 1500 ms; GABA; MR spectroscopy; N-acetyl resonance frequencies; N-acetylaspartate; N-acetylated amino acids; PRESS sequence; SAGE/IDL program; choline chloride; creatine; glutamate; glutamine; high performance liquid chromatography; metabolite ratios; myo-inositol; noninvasive brain NAA concentration quantification; position resolved spectroscopy sequence; swine model; Animals; Biomedical imaging; Brain modeling; Equations; In vitro; In vivo; Measurement standards; Sequences; Spectroscopy; Tellurium; Magnetic resonance spectroscopy; NAA concentration; PRESS sequence; metabolite; quantification;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1616690
Filename :
1616690
Link To Document :
بازگشت