DocumentCode :
1608884
Title :
On line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment
Author :
Bethge, A. ; Lo, P.K. ; Philipson, J.T. ; Weidner, J.R.
Author_Institution :
Siemens AG, Berlin, Germany
fYear :
1997
Firstpage :
267
Lastpage :
273
Abstract :
The paper describes a joint collaboration program between a major large machine and a petrochemical manufacturer to investigate the effectiveness of time and frequency domain techniques for the online monitoring of the health of high-voltage machine stator insulation systems. Information is given on the factory and site testing carried out its well as on the analysis and discussion of the results. It is concluded that both techniques can be used in the petrochemical environment for general assessments, but the time domain technique is required if identification of specific locations of discharge sites is needed
Keywords :
computerised monitoring; electric machines; frequency-domain analysis; insulation testing; machine insulation; machine testing; partial discharges; petroleum industry; stators; time-domain analysis; electric breakdown tests; frequency domain techniques; high-voltage machine stator insulation; machine insulation testing; online partial discharge monitoring; petrochemical industry; time domain techniques; Condition monitoring; Frequency domain analysis; Insulation; Online Communities/Technical Collaboration; Partial discharges; Petrochemicals; Production facilities; Pulp manufacturing; Stator windings; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Petroleum and Chemical Industry Conference, 1997. Record of Conference Papers. The Institute of Electrical and Electronics Engineers Incorporated Industry Applications Society 44th Annual
Conference_Location :
Banff, Alta.
ISSN :
0090-3507
Print_ISBN :
0-7803-4217-8
Type :
conf
DOI :
10.1109/PCICON.1997.648192
Filename :
648192
Link To Document :
بازگشت